Gas Sense Controller Units 

The Gas Sense range of controller units includes the GA-ADR addressable controller and the GA-300 series of two-channel and four-channel analogue controllers.


GA-ADR Addressable Controller

The GA-ADR addressable controller offers easy setup and flexible operation. Connect, monitor and configure up to 247 detectors on a single Modbus serial line. Create automation zones and expand the system through our modular architecture.

GA-300 Series Analogue Controllers

The GA-300 controller is an easy-to-use, cost-effective solution for projects that require 1-4 detection zones. It is a highly reliable analogue unit, equipped with all necessary functionality for industrial and commercial detector monitoring.

Overview
Applications
Compare Products

Gas Sense Analogue and Addressable Controller Units

The Gas Sense range of controller units includes the GA-ADR addressable controller and the GA-300 series of two-channel and four-channel analogue controllers. Both models are available for DIN-rail mounting or in panel configuration.

The GA-ADR and GA-300 series controller units offer in-built sound and light signalization, integrated relay outputs and continuous detector diagnostics with universal compatibility across the entire Gas Sense range of fixed detectors.

Review individual product pages for more information on detector compatibility, features and resources.

Contact us for more information.

Applications Target Gasses 
Administrative Buildings  Explosive and Toxic Gasses
Battery Rooms H2, SO2, Explosive Gasses
Bio Waste   CH4, H2S
Hydro and Thermo Power Stations CO, Explosive Gasses
Water Treatment Plants CH4, H2S, Cl2, O2
Coal Production and Storage  O2, CO2, Explosive Gasses
Welding Facilities  Explosive and Toxic Gasses
Industrial Furnaces  СО, О2, SO2, NO2, Explosive Gasses
Boiler Rooms Explosive Gasses
Steam and Gas Turbines H2, CO, O2, Explosive Gasses
Oil & Gas Processing and Storage  H2S, CO, O2, Explosive Gasses 
Plastic and Glass Production  Explosive and Toxic Gasses
Paper and Cellulose Manufacturing Explosive, H2S, Cl2
Restaurants and Kitchen Units Explosive Gasses
Manufacture of Dyes and Pigments, Paints and Varnishes Explosive and Toxic Gasses 
Printers Explosive and Toxic Gasses
Painting Chambers Explosive Gasses
Tunnels and Underground Garages Explosive Gasses, CO, NO, NO2
GA-300.E02 GA-300.E04 GA-ADR
Operating Voltage 230VAC/12VDC 230VAC/12VDC 18-30VDC
Communications Protocol Analogue (4-20mA) Analogue (4-20mA) Modbus RTU (RS-485)
Max. Number of Detectors 2 4 32 (expandable to 247)
Output  Separate SPDT Relays for Danger and Fault, Common SPDT Relay for Alarm  Separate SPDT Relays for Danger and Fault, Common SPDT Relay for Alarm  Common SPDT Relays for Alarm 1, Alarm 2, Alarm 3 and Fault
Display No No  Yes
Event Logging No  No  Yes
Detector Configuration No  No  Yes
Real-Time Detector Monitoring No  No  Yes