Gas Sense Controller Units
The Gas Sense range of controller units includes the GA-ADR addressable controller and the GA-300 series of two-channel and four-channel analogue controllers.
The Gas Sense range of controller units includes the GA-ADR addressable controller and the GA-300 series of two-channel and four-channel analogue controllers.
The GA-ADR addressable controller offers easy setup and flexible operation. Connect, monitor and configure up to 247 detectors on a single Modbus serial line. Create automation zones and expand the system through our modular architecture.
The GA-300 controller is an easy-to-use, cost-effective solution for projects that require 1-4 detection zones. It is a highly reliable analogue unit, equipped with all necessary functionality for industrial and commercial detector monitoring.
The Gas Sense range of controller units includes the GA-ADR addressable controller and the GA-300 series of two-channel and four-channel analogue controllers. Both models are available for DIN-rail mounting or in panel configuration.
The GA-ADR and GA-300 series controller units offer in-built sound and light signalization, integrated relay outputs and continuous detector diagnostics with universal compatibility across the entire Gas Sense range of fixed detectors.
Review individual product pages for more information on detector compatibility, features and resources.
Applications | Target Gasses |
Administrative Buildings | Explosive and Toxic Gasses |
Battery Rooms | H2, SO2, Explosive Gasses |
Bio Waste | CH4, H2S |
Hydro and Thermo Power Stations | CO, Explosive Gasses |
Water Treatment Plants | CH4, H2S, Cl2, O2 |
Coal Production and Storage | O2, CO2, Explosive Gasses |
Welding Facilities | Explosive and Toxic Gasses |
Industrial Furnaces | СО, О2, SO2, NO2, Explosive Gasses |
Boiler Rooms | Explosive Gasses |
Steam and Gas Turbines | H2, CO, O2, Explosive Gasses |
Oil & Gas Processing and Storage | H2S, CO, O2, Explosive Gasses |
Plastic and Glass Production | Explosive and Toxic Gasses |
Paper and Cellulose Manufacturing | Explosive, H2S, Cl2 |
Restaurants and Kitchen Units | Explosive Gasses |
Manufacture of Dyes and Pigments, Paints and Varnishes | Explosive and Toxic Gasses |
Printers | Explosive and Toxic Gasses |
Painting Chambers | Explosive Gasses |
Tunnels and Underground Garages | Explosive Gasses, CO, NO, NO2 |
GA-300.E02 | GA-300.E04 | GA-ADR | |
Operating Voltage | 230VAC/12VDC | 230VAC/12VDC | 18-30VDC |
Communications Protocol | Analogue (4-20mA) | Analogue (4-20mA) | Modbus RTU (RS-485) |
Max. Number of Detectors | 2 | 4 | 32 (expandable to 247) |
Output | Separate SPDT Relays for Danger and Fault, Common SPDT Relay for Alarm | Separate SPDT Relays for Danger and Fault, Common SPDT Relay for Alarm | Common SPDT Relays for Alarm 1, Alarm 2, Alarm 3 and Fault |
Display | No | No | Yes |
Event Logging | No | No | Yes |
Detector Configuration | No | No | Yes |
Real-Time Detector Monitoring | No | No | Yes |